Specifications
Typical solar heating errors:
Conditions of high solar radiation and wind speeds less than 1 m/s. Measurements made in comparison to an aspirated shield.
MET21 : +0.5 °C
These errors can be as little as half those of other similar shields on the market.
The performance is not dissimilar to large Stevenson screens, although the time constant of these shields is shorter.
Probe compatibility:
MET21: houses larger probes 14-25 mm in diameter taking up to 220 mm of the probe inside the shield. It can house the CS215, HC2S3, HMP45, HMP155, MP100A or smaller probes such as the 107 or PT100 using an adaptor.
Material Specifications:
Double louvered high impact thermoplastic - White external layer, with U.V. stabiliser for long-term weather resistance, extra black internal layer
Aluminium arm, powder coated in white – with phosphate pre-treatment.
A4 grade (316), stainless steel ‘V’ bolt, and securing nuts to fit a pole of between 25-51 mm diameter
Black acetal plastic locating clamp
Overall size:165 diameter x 274 mm height (Shield only); 405 mm height including bracket. Weight 1.32 kg