4WHB10K 10-kohm, Four-Wire Half-Bridge Terminal Input Module

Overview

The 4WHB10K provides the completion resistor required for four-wire half-bridge measurements. This module should be used with sensors that have a 10 kΩ resistance.

Read More

Benefits and Features

  • Makes accurate measurement of 10-kohm, 4-wire half bridges simple
  • Easy to install or remove
  • Connects directly into data logger input terminals
  • Compatible with most Campbell Scientific data loggers

Technical Description

4WHB10K Schematic 

4WHB10K-to-Sensor Hookup

Images


Specifications

Used With 4-wire half bridge measurements with a 10 kΩ resistance
Resistance 10 kΩ (bulk metal foil)
Tolerance ±0.01% (@ 25°C)
Maximum Temperature Coefficient ±0.8 ppm/°C
Power Rating 0.25 W (@ 70°C)
Dimensions 1.5 x 1.5 x 2.7 cm (0.6 x 0.6 x 1.0 in.) for body with prongs
Weight 6 g (0.2 oz)

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Dataloggers

Product Compatible Note
CR1000 (retired)
CR200X (retired)
CR216X (retired)
CR300 (retired)
CR3000
CR310
CR350
CR5000 (retired)
CR6
CR800 (retired)
CR850 (retired)

Miscellaneous

Product Compatible Note
CR9050 (retired)

Additional Compatibility Information

Data Logger Considerations

The 4WHB10K uses two sequential differential analog inputs; the first differential channel must have an adjacent analog ground channel to accept the "ground prong" of the 4WHB10K. Not all data logger terminal strips have this sequence on all channels, so please check your data logger's wiring panel to confirm channel assignments, especially if you plan to use multiple Terminal Input Modules.

Newer CR10X Wiring Panels and the CR10XTCR Thermocouple Cover are deep enough to cover the data logger input channels with a Terminal Input Module attached; older CR10TCRs are not deep enough.

Programming

The 4WHB10K is measured either with CRBasic's BrHalf4W Instruction or Edlog's Instruction 9 (Full-Bridge with Excitation Compensation).