CS325DMCBL-L Replacement Cable for the CS325DM-L

Overview

The CS325DM cable is used for differentially transmitting data and power over twisted pairs to the CS325DM-L Silicon Irradiance Reference Sensor. This premium industrial Ethernet cable has controlled characteristic impedance for each twisted pair, making it suitable for maintaining high signal fidelity on the RS-485 signals with minimal signal reflections and excellent noise rejection. Jacket material is designed for outdoor use including UV exposure resistance and temperature performance of -40 to +75°C. Agency approvals include UL AWM Style 2463 (80C, 600V) and NEC/CEC (UL) CMX OUTDOOR. The cable has a high-flex construction with a jacket that can be pulled in conduit in addition to its resistance to weld spatter and oil.

The CS325DMCBL-L includes a connector on one side of the cable for matching any user-specified length of 33117 Ethernet cable to a CS325DM Silicon Irradiance Reference Sensor. The other side of the cable is pigtailed and tinned.

Read More

Benefits and Features

  • NEC, UL, and CEC OUTDOOR rated, premium industrial grade
  • Outdoor rated with excellent UV, temperature, and voltage ratings
  • Differentially transmitted data with excellent noise rejection
  • High-flex construction that can be pulled through conduit
  • Suitable for POE
  • Fire, cutting/machining oil, and weld splatter resistant

Technical Description

Wiring Diagram

Pin Wire Color Function
3 Blue RS-485 A/A' [-]
2 White/Blue

RS-485 B/B' [+]

4 White/Brown

12V Vdc

1 Brown

Power Ground

5 Green

Modbus Common

Images

Specifications

Maximum Temperature Rating 75°C and 80°C (jacket 105°C; oil 75°C)
Minimum Temperature Rating -40°C
Conductor Material 22 AWG 19/0.0058 stranded tinned copper
Insulation Material High-density polyethylene 0.254 mm (0.01 in.) nominal wall thickness
Pairs Color-coded singles twisted into pairs
  1. WHITE/BLUE X BLUE
  2. WHITE/ORANGE X ORANGE
  3. WHITE/GREEN X GREEN
  4. WHITE/BROWN X BROWN
Cable Type 4 twisted pairs twisted together and wrapped with clear polyester tape to form a cable core
Jacket Material Thermoplastic elastomer, 1.07 mm (0.042 in.) nominal wall thickness (pressure)
Voltage Rating 600 V (maximum) for 100 m (328.08 ft ) of cable
DC Resistance 6.0 Ω (maximum) for 100 m (328.08 ft ) of cable
Impedance
  • 100 ± 15 Ω 1 to 100 MHz for 100 m (328.08 ft ) of cable
  • 100 ± 20 Ω 100 to 350 MHz for 100 m (328.08 ft ) of cable
Nominal Mutual Capacitance 13.5 PF/FT. at 1 MHz
Approvals
  • UL AWM 2463 (80C 600V)
  • NEC (UL) TYPE PLTC
  • NEC (UL) TYPE CMX OUTDOOR – CM
  • CEC C(UL) TYPE CMX OUTDOOR – CM
  • PENNSYLVANIA D.E.P. – MSHA
Compliance Information
  • POE compliant (802.3af) to 100 meters when installed per recommendations in TIA TSB-184.
  • Cable will meet CAT5e channel requirements to 100 meter length.
  • RoHS compliant materials
Conductor Diameter 0.71 mm (0.028 in.)
Insulation Diameter 1.22 mm (0.048 in.) maximum
Pairs Diameter 2.49 mm (0.098 in.)
Cable Diameter 5.23 mm (0.206 in.)
Overall Cable Diameter 7.37 mm nominal ± 0.13 mm (0.29 in. nominal ± 0.005 in.)
Weight 18.82 kg (41.5 lb)

Downloads

CS325DM Program Examples v.2 (3 KB) 11-01-2022

Two CR1000X data logger programs that read the CS325DM measurements. An example program is included for each output option (digital Modbus, analog). Program code for other data logger models will be similar. 

Listed Under

Replacement Part for the following products:

Privacy Policy Update

We've updated our privacy policy.  Learn More

Cookie Consent

Update your cookie preferences.  Update Cookie Preferences